GigaLine® KL-I-V(ZN)HH Eca
Breakout indoor cable, STB900
6 x 1 G50/125/250 OM3

GL_C_I-V(ZN)HH_MM_8_WBU_3D.jpg

Properties / Applications

Properties: Indoor cable for fixed installation.

Application: Connecting cable and patch cord for generic cabling systems acc. to ISO/IEC 11801 and EN 50173. Ideal for all applications of Classes OF 300 to OF 2000. Suitable for direct connector mounting with adhesive technology. Not suitable for crimp connector assembly where the fixation takes place via the secondary coating.

Description

Fibre optic indoor cable,with buffered fibres, break out

Product information

Part number: LKD8BA520130000

Follow-up product: KDFBE3K44300000

Category: OM3

Fire class: Eca

DoP: CDESK0000085

Number of fibres: 6

Technical information

Bending radius (static) (min.): 10x outer-Ø

Bending radius (dynamic) (min.): 15x outer-Ø

Bending radius single element: 30 mm

Transport / storage: -25 °C up to + 70 °C

During installation: -5 °C up to +50 °C

After installation: -5 °C up to +70 °C

Flame retardancy: IEC 60332-1-2 IEC 60332-3-22 Cat. A

Halogen-free: IEC 60754-1

Acidity: IEC 60754-2

Smoke density: IEC 61034-1