Back

GigaLine® Dca
Breakout indoor cable, fig. 0
2 x 1 G50/125/250 OM3

GL_C_I-V(ZN)HH_fig0_MM_2_WBU_3D.jpg

Properties / Applications

Properties: Indoor cable for use as patchcord

Application: Connecting cable and patch cord for generic cabling systems acc. to ISO/IEC 11801 and EN 50173. Ideal for all applications of Classes OF 300 to OF 2000. Suitable for direct connector mounting with adhesive technology. Not suitable for crimp connector assembly where the fixation takes place via the secondary coating.

Description

Fibre optic indoor cable,with semi tight buffered fibres, duplex fig. 0.

Product information

Part number: KDF1D3K22300000

Application: Office DataCenter Industry

Category: OM3

Fire class: Dca -s1a,d1,a1

DoP: CDESK0000081

Number of fibres: 2

Technical information

Bending radius single element: 30 mm

Transport / storage: -25 °C up to + 70 °C

During installation: -5 °C up to +50 °C

After installation: -10 °C up to +70 °C

Flame retardancy: IEC 60332-1-2 IEC 60332-3-22 Cat. A

Halogen-free: IEC 60754-1

Acidity: IEC 60754-2

Smoke density: IEC 61034-1

Back